Updated: Oct 11, 2026
No. of Questions: 33 Questions & Answers with Testing Engine
Download Limit: Unlimited
Each questions and answers torrent of Exams-boost are edited and summarized by our specialist with utmost care and professionalism. What you get from the NCM-MCI-6.10 exam training torrent is not only just passing the exam successfully, but also enlarging your scope of knowledge and enriching your future. Nutanix NCM-MCI-6.10 free download pdf is really trustworthy for you to depend on
Exams-boost has an unprecedented 99.6% first time pass rate among our customers.
We're so confident of our products that we provide no hassle product exchange.
| Certification Vendor: | Nutanix |
|---|---|
| Exam Name: | Nutanix Certified Master - Multicloud Infrastructure (NCM-MCI) v6.10 |
| Exam Number: | NCM-MCI-6.10 |
| Real Exam Qty: | 16-20 scenarios |
| Related Certifications: | NCM (Nutanix Certified Master) NCP (Nutanix Certified Professional) |
| Available Languages: | English |
| Exam Duration: | 180 minutes |
| Exam Price: | $300 USD per attempt |
| Exam Format: | Live Lab Environment, Scenario-based practical tasks |
| Recommended Training: | Nutanix University Certification Training |
| Exam Registration: | Nutanix Certification Portal |
| Sample Questions: | Nutanix NCM-MCI-6.10 Sample Questions |
| Exam Way: | Live lab, scenario-based practical assessment (remote proctored environment) |
| Pre Condition: | Candidates must hold a valid, non-expired NCP or NCM certification and typically have 2–5 years of infrastructure experience with 2–3 years Nutanix experience |
| Official Syllabus URL: | https://www.nutanix.com/en_gb/support-services/training-certification/certifications/certification-details-ncm-mci |
| Section | Objectives |
|---|---|
| Topic 1: Analyze and Optimize Storage Performance | - Storage internals and I/O analysis - Storage configuration optimization - Workload performance evaluation |
| Topic 2: Business Continuity | - Workload resilience evaluation - BCDR compliance analysis |
| Topic 3: Analyze and Optimize Network Performance | - Advanced network configuration - Flow policies analysis and optimization - Physical and virtual network evaluation - Overlay networking optimization |
| Topic 4: Analyze and Optimize VM Performance | - Cluster and node metrics analysis - VM resource optimization |
| Topic 5: Advanced Configuration and Troubleshooting | - Security posture analysis - Troubleshooting Nutanix services - Risk mitigation configuration - Third-party integrations - CLI and API execution |
Task 5
An administrator has noticed that after a host failure, the SQL03 VM was not powered back on from another host within the cluster. The Other SQL VMs (SQL01, SQL02) have recovered properly in the past.
Resolve the issue and configure the environment to ensure any single host failure affects a minimal number os SQL VMs.
Note: Do not power on any VMs
Correct Answer:
See the Explanation for step by step solution.
Explanation:
One possible reason why the SQL03 VM was not powered back on after a host failure is that the cluster was configured with the default (best effort) VM high availability mode, which does not guarantee the availability of VMs in case of insufficient resources on the remaining hosts. To resolve this issue, I suggest changing the VM high availability mode to guarantee (reserved segments), which reserves some memory on each host for failover of VMs from a failed host. This way, the SQL03 VM will have a higher chance of being restarted on another host in case of a host failure.
To change the VM high availability mode to guarantee (reserved segments), you can follow these steps:
Log in to Prism Central and select the cluster where the SQL VMs are running.
Click on the gear icon on the top right corner and select Cluster Settings.
Under Cluster Services, click on Virtual Machine High Availability.
Select Guarantee (Reserved Segments) from the drop-down menu and click Save.
To configure the environment to ensure any single host failure affects a minimal number of SQL VMs, I suggest using anti-affinity rules, which prevent VMs that belong to the same group from running on the same host. This way, if one host fails, only one SQL VM will be affected and the other SQL VMs will continue running on different hosts.
To create an anti-affinity rule for the SQL VMs, you can follow these steps:
Log in to Prism Central and click on Entities on the left menu.
Select Virtual Machines from the drop-down menu and click on Create Group.
Enter a name for the group, such as SQL Group, and click Next.
Select the SQL VMs (SQL01, SQL02, SQL03) from the list and click Next.
Select Anti-Affinity from the drop-down menu and click Next.
Review the group details and click Finish.
I hope this helps. How else can I help?
https://portal.nutanix.com/page/documents/details?targetId=AHV-Admin-Guide-v6_5:ahv-affinity-policies-c.html
A screenshot of a computer Description automatically generated with medium confidence
TASK 1
A newly created Windows VM "SQL02" is experiencing poor storage performance when compared to
"SQL01" running within the same cluster, on the same storage container.
The cluster is in a healthy state.
Create a new session named Monitor SQL02 with meaningful metrics. Right click on the session page and click Select All then paste this into Notepad and save it as Task 1.txt on the desktop.
Also, save the analysis as a report named MonitorSQL02 and send the report as a PDF on a daily basis to [email protected]. Reports should not be retained. If any new objects need to be created, use monitovm2 in the name.
Finally, correct the issue within "SQL02".
Notes:
* Do not power on the VMs.
* While you will be creating a session, you will need to examine the VM configurations to determine the issue.
* Do not delete the VM to resolve the issue, any other destructive change is acceptable.
Correct Answer:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to all three tasks, performed within the Nutanix Prism interface.
Task 1: Create Monitoring Session & Save Metrics
* From the Prism Central dashboard, navigate to Operations > Analysis.
* Click the + New Session button.
* Name the session Monitor SQL02.
* In the "Entities" search box, type SQL01 and select VM: SQL01.
* In the "Entities" search box, type SQL02 and select VM: SQL02.
* Click Add Charts > New Chart.
* Title: Storage IOPS
* Metric: Storage Controller IOPS
* Click Add.
* Click Add Charts > New Chart.
* Title: Storage Latency
* Metric: Storage Controller Latency
* Click Add.
* Click Add Charts > New Chart.
* Title: Storage Bandwidth
* Metric: Storage Controller Bandwidth
* Click Add.
* Click Save Session.
* With the "Monitor SQL02" session open, right-click anywhere on the page and click Select All.
* Right-click again and select Copy.
* Open Notepad, paste the content, and save the file to the desktop as Task 1.txt.
(The content pasted into Task 1.txt would be the session's chart configurations, showing metrics for SQL01 and SQL02.)
Task 2: Create and Schedule the Report
* While still in the "Monitor SQL02" analysis session, click the Save as Report button (it looks like a bookmark icon).
* Name the report MonitorSQL02 and click Save.
* Navigate to Operations > Reports.
* Find the MonitorSQL02 report in the list. Select its checkbox.
* Click the Actions dropdown and select Schedule.
* Configure the schedule with the following settings:
* Schedule Name: monitovm2_daily_report
* Recurrence: Daily
* Start Time: (Set to a time, e.g., 8:00 AM)
* Repeat every: 1 day(s)
* Retention Policy: Uncheck the "Retain a copy of the report" box. (This ensures reports are not retained).
* Email Report: Check this box.
* Format: PDF
* Recipients: [email protected]
* Click Save.
Task 3: Identify and Correct the Performance Issue
This task is performed without powering on the VMs, indicating a configuration error.
Investigation
* Navigate to VMs > Table view.
* Click on the SQL01 (the good VM) and select the Configuration tab.
* Expand the Disks section. Observe that the primary disk is attached to a SCSI bus (e.g., scsi.0). This is the high-performance standard.
* Return to the VM list and click on SQL02 (the problem VM).
* Expand the Disks section.
Root Cause
You discover that the primary disk for SQL02 is attached to an IDE bus. The IDE bus has significant performance limitations and is not suitable for a database server, causing the poor storage performance.
Correction
* With the SQL02 VM selected, click the Update button.
* In the "Update VM" dialog, scroll down to the Disks section.
* Find the disk attached to the IDE bus. Click the Edit (pencil) icon for that disk.
* Change the Bus Type dropdown from IDE to SCSI.
* The Device Index will automatically populate (e.g., scsi.0).
* Click Save in the "Update Disk" dialog.
* (Note: A "VirtIO SCSI Controller" will be automatically added to the VM configuration if one was not already present.)
* Click Save in the "Update VM" dialog.
The VM SQL02 is now configured to use the high-performance VirtIO-SCSI controller, which will resolve the storage performance discrepancy once the VM is powered on.
Task 1
An administrator needs to configure storage for a Citrix-based Virtual Desktop infrastructure.
Two VDI pools will be created
Non-persistent pool names MCS_Pool for tasks users using MCS Microsoft Windows 10 virtual Delivery Agents (VDAs) Persistent pool named Persist_Pool with full-clone Microsoft Windows 10 VDAs for power users
20 GiB capacity must be guaranteed at the storage container level for all power user VDAs The power user container should not be able to use more than 100 GiB Storage capacity should be optimized for each desktop pool.
Configure the storage to meet these requirements. Any new object created should include the name of the pool (s) (MCS and/or Persist) that will use the object.
Do not include the pool name if the object will not be used by that pool.
Any additional licenses required by the solution will be added later.
Correct Answer:
See the Explanation for step by step solution.
Explanation:
To configure the storage for the Citrix-based VDI, you can follow these steps:
Log in to Prism Central using the credentials provided.
Go to Storage > Storage Pools and click on Create Storage Pool.
Enter a name for the new storage pool, such as VDI_Storage_Pool, and select the disks to include in the pool.
You can choose any combination of SSDs and HDDs, but for optimal performance, you may prefer to use more SSDs than HDDs.
Click Save to create the storage pool.
Go to Storage > Containers and click on Create Container.
Enter a name for the new container for the non-persistent pool, such as MCS_Pool_Container, and select the storage pool that you just created, VDI_Storage_Pool, as the source.
Under Advanced Settings, enable Deduplication and Compression to reduce the storage footprint of the non- persistent desktops. You can also enable Erasure Coding if you have enough nodes in your cluster and want to save more space. These settings will help you optimize the storage capacity for the non-persistent pool.
Click Save to create the container.
Go to Storage > Containers and click on Create Container again.
Enter a name for the new container for the persistent pool, such as Persist_Pool_Container, and select the same storage pool, VDI_Storage_Pool, as the source.
Under Advanced Settings, enable Capacity Reservation and enter 20 GiB as the reserved capacity. This will guarantee that 20 GiB of space is always available for the persistent desktops. You can also enter 100 GiB as the advertised capacity to limit the maximum space that this container can use. These settings will help you control the storage allocation for the persistent pool.
Click Save to create the container.
Go to Storage > Datastores and click on Create Datastore.
Enter a name for the new datastore for the non-persistent pool, such as MCS_Pool_Datastore, and select NFS as the datastore type. Select the container that you just created, MCS_Pool_Container, as the source.
Click Save to create the datastore.
Go to Storage > Datastores and click on Create Datastore again.
Enter a name for the new datastore for the persistent pool, such as Persist_Pool_Datastore, and select NFS as the datastore type. Select the container that you just created, Persist_Pool_Container, as the source.
Click Save to create the datastore.
The datastores will be automatically mounted on all nodes in the cluster. You can verify this by going to Storage > Datastores and clicking on each datastore. You should see all nodes listed under Hosts.
You can now use Citrix Studio to create your VDI pools using MCS or full clones on these datastores. For more information on how to use Citrix Studio with Nutanix Acropolis, see Citrix Virtual Apps and Desktops on Nutanix or Nutanix virtualization environments.

https://portal.nutanix.com/page/documents/solutions/details?targetId=BP-2079-Citrix-Virtual-Apps-and- Desktops:bp-nutanix-storage-configuration.html
Task 6
An administrator needs to assess performance gains provided by AHV Turbo at the guest level.
To perform the test the administrator created a Windows 10 VM named Turbo with the following configuration.
1 vCPU
8 GB RAM
SATA Controller
40 GB vDisk
The stress test application is multi-threaded capable, but the performance is not as expected with AHV Turbo enabled. Configure the VM to better leverage AHV Turbo.
Note: Do not power on the VM. Configure or prepare the VM for configuration as best you can without powering it on.
Correct Answer:
To configure the VM to better leverage AHV Turbo, you can follow these steps:
Log in to Prism Element of cluster A using the credentials provided.
Go to VM > Table and select the VM named Turbo.
Click on Update and go to Hardware tab.
Increase the number of vCPUs to match the number of multiqueues that you want to enable. For example, if you want to enable 8 multiqueues, set the vCPUs to 8. This will improve the performance of multi-threaded workloads by allowing them to use multiple processors.
Change the SCSI Controller type from SATA to VirtIO. This will enable the use of VirtIO drivers, which are required for AHV Turbo.
Click Save to apply the changes.
Power off the VM if it is running and mount the Nutanix VirtIO ISO image as a CD-ROM device. You can download the ISO image from Nutanix Portal.
Power on the VM and install the latest Nutanix VirtIO drivers for Windows 10. You can follow the instructions from Nutanix Support Portal.
After installing the drivers, power off the VM and unmount the Nutanix VirtIO ISO image.
Power on the VM and log in to Windows 10.
Open a command prompt as administrator and run the following command to enable multiqueue for the VirtIO NIC:
ethtool -L eth0 combined 8
Replace eth0 with the name of your network interface and 8 with the number of multiqueues that you want to enable. You can use ipconfig /all to find out your network interface name.
Restart the VM for the changes to take effect.
You have now configured the VM to better leverage AHV Turbo. You can run your stress test application again and observe the performance gains.
https://portal.nutanix.com/page/documents/kbs/details?targetId=kA00e000000LKPdCAOchangev
CPUto 2/4 ?
Change SATA Controller to SCSI:
acli vm.get Turbo
Output Example:
Turbo {
config {
agent_vm: False
allow_live_migrate: True
boot {
boot_device_order: "kCdrom"
boot_device_order: "kDisk"
boot_device_order: "kNetwork"
uefi_boot: False
}
cpu_passthrough: False
disable_branding: False
disk_list {
addr {
bus: "ide"
index: 0
}
cdrom: True
device_uuid: "994b7840-dc7b-463e-a9bb-1950d7138671"
empty: True
}
disk_list {
addr {
bus: "sata"
index: 0
}
container_id: 4
container_uuid: "49b3e1a4-4201-4a3a-8abc-447c663a2a3e"
device_uuid: "622550e4-fb91-49dd-8fc7-9e90e89a7b0e"
naa_id: "naa.6506b8dcda1de6e9ce911de7d3a22111"
storage_vdisk_uuid: "7e98a626-4cb3-47df-a1e2-8627cf90eae6"
vmdisk_size: 10737418240
vmdisk_uuid: "17e0413b-9326-4572-942f-68101f2bc716"
}
flash_mode: False
hwclock_timezone: "UTC"
machine_type: "pc"
memory_mb: 2048
name: "Turbo"
nic_list {
connected: True
mac_addr: "50:6b:8d:b2:a5:e4"
network_name: "network"
network_type: "kNativeNetwork"
network_uuid: "86a0d7ca-acfd-48db-b15c-5d654ff39096"
type: "kNormalNic"
uuid: "b9e3e127-966c-43f3-b33c-13608154c8bf"
vlan_mode: "kAccess"
}
num_cores_per_vcpu: 2
num_threads_per_core: 1
num_vcpus: 2
num_vnuma_nodes: 0
vga_console: True
vm_type: "kGuestVM"
}
is_rf1_vm: False
logical_timestamp: 2
state: "Off"
uuid: "9670901f-8c5b-4586-a699-41f0c9ab26c3"
}
acli vm.disk_create Turbo clone_from_vmdisk=17e0413b-9326-4572-942f-68101f2bc716 bus=scsi remove the old disk acli vm.disk_delete 17e0413b-9326-4572-942f-68101f2bc716 disk_addr=sata.0
Everything goes well.
From now on, whatever I need, I will come back to take.
Thank you guys for the NCM-MCI-6.10 perfect job.
That was a wise dicision, I have passed NCM-MCI-6.10.
Thank you!
Still valid NCM-MCI-6.10 dumps.
Thanks for Master Level sending me the update.
Thanks very much for NCM-MCI-6.10 exam dumps
Disclaimer Policy: The site does not guarantee the content of the comments. Because of the different time and the changes in the scope of the exam, it can produce different effect. Before you purchase the dump, please carefully read the product introduction from the page. In addition, please be advised the site will not be responsible for the content of the comments and contradictions between users.
We have built a strong and professional team devoting to the research of NCM-MCI-6.10 valid practice torrent. The experts of the team are all with rich hands-on experience and ever work for the international corporations. The authority and validity of NCM-MCI-6.10 training torrent are the guarantee for all the candidates. Now, NCM-MCI-6.10 valid exam torrent will provide you with the best suitable training material for you to study.
Or in case of failure, we have money back guarantee policy that if you fail exam after purchasing our NCM-MCI-6.10 practice test engine, we will full refund to you soon if you send us your failure score scanned and apply for refund. No Pass, Full Refund!
Yes, our NCM-MCI-6.10 exam questions are certainly helpful practice materials. Our pass rate is 99%. Our NCM-MCI-6.10 exam questions are compiled strictly. Our education experts are experienced in this line many years. We guarantee that our materials are helpful and latest surely. If you want to know more about our products, you can download our PDF free demo for reference. Also we have pictures and illustration for Self Test Software & Online Engine version.
All our products are the latest version. If you want to know details about each exam materials, our service will be waiting for you 7*24*365 online. Our exam products will updates with the change of the real NCM-MCI-6.10 test. It is different for each exam code.
All our products can share 365 days free download for updating version from the date of purchase. So don't worry. The exam materials will be valid for 365 days on our site.
We have professional system designed by our strict IT staff. Once the NCM-MCI-6.10 exam materials you purchased have new updates, our system will send you a mail to notify you including the downloading link automatically, or you can log in our site via account and password, and then download any time. As we all know, procedure may be more accurate than manpower.
No. After purchase, our system will set up an account and password by your purchasing information. You can use it directly or you can change your password as you like. No need to register an account yourself.
Yes, we have money back guarantee if you fail exam with our products. Applying for refund is simple that you send email to us for applying refund attached your failure score scanned. Money will be back to what you pay. Normally we support Credit Card for most countries. Our refund validity is 60 days from the date of your purchase. Our customer service is 365 days warranty. Users can receive our latest materials within one year.
Self Test Software should be downloaded and installed in Window system with Java script. After purchase, we will send you email including download link, you click the link and download directly. If your computer is not the Window system and Java script, you can choose to purchase Online Test Engine. It is available for all device such Mac.
Yes, you can choose PDF version and print out. PDF version, Self Test Software and Online Test Engine cover same questions and answers. PDF version is printable.
Self Test Software can be downloaded in more than two hundreds computers. It is no limitation for the quantity of computers. So does Online Test Engine. You can use Online Test Engine in any device.
Over 61965+ Satisfied Customers
