
EMC D-PE-OE-23 Exam Info and Free Practice Test | Exams-boost
Pass EMC D-PE-OE-23 Premium Files Test Engine pdf - Free Dumps Collection
NEW QUESTION # 13
A technician needs to update the iDRAC license on a PowerEdge R740 server from Express to Enterprise.
The server has the following components:
- 2x CPUs
- 384 GB RAM
- 6x 1 TB drives
- 1x PSU
The server is powered down but connected to active AC. The user wants it to stay powered down and not connect to any networks. No errors are presently displayed.
How can the technician upgrade the license?
- A. Connect to the iDRAC GUI and upgrade the iDRAC license while the server is powered down.
- B. The license cannot be upgraded because the user will not allow the server to be powered on
- C. The license cannot be upgraded on a single PSU system
- D. Power on the server then connect to the iDRAC and upgrade iDRAC license before powering the server down
Answer: A
NEW QUESTION # 14
A technician is changing the iDRAC IP address from the static IP address 10.37.125.88 to DHCP on the technician's PowerEdge R640 that does not have a front LCD. After completing this task, they are unable to determine which IP address was given to the iDRAC and they cannot reboot the server.
What method could the technician use to determine what IP address is assigned to the iDRAC?
- A. Log in to the Lifecycle and check the iDRAC Settings.
- B. Use the iDRAC Direct feature. Access iDRAC web GUI and determine the assigned IP address
- C. Hold the system identification button down for more than 3 seconds to reset it back to the default static address 192.168.0.120
- D. Plug a monitor or KVM into the system. Reboot the server to view the assigned IP iDRAC address on the Dell boot up splash screen
Answer: B
NEW QUESTION # 15
A user has a service with only one processor installed with 6x 32 GB ROIMMs. A technician was asked to install a second processor. After installing the second processor, the technician finds that the second processor is not operational.
What should be done to make the second processor operation?
- A. The iDRAC license needs to be at either Express or Enterprise levels
- B. Logical processor must be enabled in the BIOS
- C. The second CPU socket needs to be enabled
- D. The ROIMMs need to be moved so that there are three RDIMMs on each CPU
Answer: D
NEW QUESTION # 16
A technician tries to power on a server but nothing happens when they press the power button. The status LEDs on both PSUs are green. The technician is able to connect to the iDRAC to review the System Event Logs and discovers that PSU2 has failed.
- A. Reboot the server
Test one PSU at a time - B. Cycle the AC power
Test one PSU at a time - C. Cycle the AC power
Reset the NVRAM - D. Reboot the server
Reset the NVRAM
Answer: B
NEW QUESTION # 17
Which export type in iDRAC restores a Server Configuration Profile to a known baseline?
- A. Basic
- B. Replacement
- C. Clone
- D. Advanced
Answer: B
NEW QUESTION # 18
A technician needs to perform a RAID controller firmware update from within the Operating System.
The server runs Red Hat Enterprise Linux and is configured with an iDRAC basic license.
Which three steps should the technician take to complete this task? (Choose three.)
- A. After firmware update, run fsck command on the virtual disks
- B. Restart the server and press F10 to start the firmware update process
- C. Obtain the latest firmware update for the RAID controller
- D. Open a command shell and execute the firmware package
- E. After the firmware update, restart the server
- F. Run racadm fwupdate command from a management station
Answer: D,E,F
NEW QUESTION # 19
Case Study 3
A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance.
However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features.
The compute and storage environment consists of the following:
- 200 TB of Fibre Channel drives on NetApp ONTAP 7
- Environment is expected to grow 200 TB over the next three years
In order to remove the encryption key on the SED drives, which steps are required?
- A. SmartFail the cluster and then remove the drive
- B. Suspend the cluster and then SmartFail the drive
- C. Suspend the node and then remove the drive
- D. SmartFail and then remove the drive
Answer: C
NEW QUESTION # 20
A technician needs to view the health status of the server and components.
Which Dell management tool should the technician install in the OS?
- A. Open Manage PowerEdge Components
- B. Open Manage Health Status
- C. Open Manage Server Administrator
- D. Open Manage Integrations
Answer: C
NEW QUESTION # 21
Which NDC options can be ordered for a Dell EMC PowerEdge R740xd server?
- A. Two 10 Gbps
Two 10 Gbps and two 25 Gbps
Four 25 Gbps - B. Four 1 Gbps
Four 10 Gbps
Two 25 Gbps and two 1 Gbps - C. Four 1 Gbps
Two 10 Gbps and two 25 Gbps
Two 25 Gbps - D. Four 10 Gbps
Two 10 Gbps and two 1 Gbps
Two 25 Gbps
Answer: D
NEW QUESTION # 22
A remote system administrator must troubleshoot a server fault.
Which step provides the information that they need?
- A. Read the installation and service manual.
- B. View the system update page in the iDRAC UI.
- C. Generate a tech support report and view the Lifecycle log.
- D. Check system setup and device settings.
Answer: C
NEW QUESTION # 23
After a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster in the future, even at the expense of stowing users down.
How should the technician perform this task?
- A. Change the Rebuild Rate in the System BIOS Settings
- B. Change the System Profile to Performance in the System BIOS Setting
- C. Change the System Profile 1o performance in the iDRAC GUI
- D. Change the Rebuild Rate from me iDRAC GUI
Answer: D
NEW QUESTION # 24
A technician has the ISO image of an OS that they need to install on a server in a remote location.
They are already logged into the iDRAC.
How should the technician install the OS?
- A. Click Launch under the Virtual Console Preview, Select Next Boot, and choose Virtual CD/DVD/ISO
- B. Click on Update and Rollback under Quick Launch Tasks
- C. Click Launch under the Virtual Console Preview, reboot the server into F10, and start the Lifecycle Controller OS Deployment wizard
- D. Click Launch under the Virtual Console Preview and then connect to Virtual Media
Answer: C
NEW QUESTION # 25
The system administrator deployed the Dell PowerEdge server. No iDRAC license was purchased with the server.
Which features are available?
- A. Advanced power monitoring, autodiscovery, and virtual folders
- B. Remote syslog, two-factor authentication, and zero touch provisioning
- C. Email alerts, advanced power monitoring, and profile-based configuration
- D. Profile-based configuration, email alerts, and directory services
Answer: C
NEW QUESTION # 26
What is a key feature of Part Replacement in Lifecycle Controller?
- A. Runs a parts replacement wizard.
- B. What is a key feature of Part Replacement in Lifecycle Controller?
- C. Automatically updates the configuration of the new part.
- D. Automatically updates the server configuration database.
Answer: C
NEW QUESTION # 27
A technician has a server in production. The iDRAC SEL log indicates a possible issue with DIMMs A1 and A2. Firmware is up to date.
What is the most efficient way to troubleshoot this issue?
- A. Swap DIMMs A1 and A2 to B1 and B2
- B. Reseat DIMMs A1 and A2
- C. Swap DIMMs A1 and A2 to A3 and A4
- D. Swap DIMMs A1 and A2 to B1 and B3
Answer: B
NEW QUESTION # 28
A technician is ready to deploy a server. If a critical part such as the system board fails, they must be able to replace the system board, reconfigure components, and update the firmware revisions in the fastest possible time.
How should the technician meet this requirement?
- A. Back up component configurations using iSM
- B. Back up the profile using the System Profile Settings
- C. Use the iDRAC Rollback feature to restore the firmware revisions
- D. Use the iDRAC GUI to back up the Server Profile
Answer: D
NEW QUESTION # 29
One of the servers in a datacenter is set to use the 1+1 power redundancy option with a hot spare.
The server uses 1100W PSUs. An SNMP trap has been sent alerting the technician to a PSU failure.
Since this is the "hot spare" PSU, the technician chooses an available, higher capacity Titanium PSU.
After replacing the PSU and connecting the power cable, the PSU indicator/handle flashes green, then turns off.
The technician has taken the following actions:
- Reseated the PSU
- Checked the firmware version
- Checked the cable connections
The PSU continues to flash green then turn off.
What should the technician do?
- A. Replace the 1100W PSU with a matching unit
- B. Check the Titanium PSU in another server to ensure it is not defective
- C. Wait for the PSU firmware to update
- D. Change the redundancy from 1+1 to 2+0 and then enable the hot spare
Answer: A
NEW QUESTION # 30
A technician replaces the system board on a Dell EMC PowerEdge server.
Using the Easy Restore function, what can be restored to the new system board without the use of a USB device, Internet connection, or DVD?
- A. BIOS configuration, RAID configuration, System Configuration settings, and iDRAC license
- B. System Configuration settings, all licenses, Service tag, and Diagnostics
- C. RAID configuration, Firmware revision, iDRAC license, and Service tag
- D. Firmware revision, Service tag, Diagnostics, and BIOS configuration
Answer: B
NEW QUESTION # 31
The operating system on a Dell PowerEdge R760xa fails to boot.
What iDRAC feature under the iDRAC UI Troubleshooting tab can be used to diagnose the issue?
- A. Post package repair
- B. POST code state
- C. System Event Logs
- D. SupportAssist collection
Answer: B
NEW QUESTION # 32
......
Updated Official licence for D-PE-OE-23 Certified by D-PE-OE-23 Dumps PDF: https://www.exams-boost.com/D-PE-OE-23-valid-materials.html
New 2024 Realistic D-PE-OE-23 Dumps Test Engine Exam Questions in here: https://drive.google.com/open?id=1g1Z2MWRmA6o25au75vsSJriZsUiu1BPa